The installation of the EVERHOT is a very simple operation that is normally carried out by ourselves or one of our dealers, however it is worth noting the points below and if you follow these simple guidelines it will ensure that everything goes well on delivery day.
Note: The preparation of the site, in readiness for the installation of the appliance, is the responsibility of the site owner, not of the manufacturer of the appliance.
- The floor must be level and capable of supporting the weight of the cooker (approximate weights: EVH 60 250kg EVH 90 300kg, EVH 100 350kg, EVH120 500kg, EVH150 550kg).
- All cookers are of standard dimensions 600mm deep and 900mm high to the working surface with widths of 600mm (EVH 60), 890mm (EVH 90), 995mm (EVH 100), 1200mm (EVH 120) or 1500mm (EVH 150). EVH 60, EVH 100, EVH 120 or EVH 150 cookers should be installed with a minimum of 30mm clearance from the back wall to allow for the electric cable entry, and induction hob venting where applicable. EVH 90 cookers should be installed with a minimum of 15mm. On no account should a cooker be pushed hard against the back wall as this may damage the electric cable, or block the induction vent. A minimum gap of 5mm per side is required to allow installation and removal of the cooker – please contact us in advance of installation if this is not possible. Where the end grain of a wooden worktop is adjacent to the cooker, we recommend that this is increased to 10mm to minimise the chance of cracking.
- Clearance must be allowed for the raising of the cooker lid(s) into the upright position (minimum height of 1530mm from ground level). A 5mm gap on each side of the cooker lid should be allowed when in the raised position (each lid is 590mm wide to allow for overhead cupboards).
- The appliance must be used on 220-240V AC only and should be plugged into a standard 13 amp socket (EVH 60 or EVH 90, EVH 100 without induction hob), or two standard 13 amp sockets (EVH 100 with induction hob, EVH 120 or EVH 150). The 13 amp socket(s) should be accessible and positioned adjacent to the cooker, so as not to impede the opening of the top lid, and ensuring the plug is not exposed to steam or excessive moisture. If the socket(s) cannot be positioned immediately adjacent to the cooker, please see diagrams attached for exact lengths of cables. If the power supply cord is damaged, it must be replaced by the manufacturer or their representative, as special purpose tools are required. An Everhot cooker should NOT be hard wired – please install using the supplied 13amp plug.
- EVH 60 or EVH 120 only - The control box is connected to the cooker via a 20mm flexible conduit to allow for a choice of positioning. It may be sited within an adjacent cupboard or on a worktop as required (the control box must not be covered by combustible material or be positioned where contamination with liquids is likely). The control box is not suitable for wall mounting and should remain freestanding in order to facilitate future maintenance. The conduit and power cable should also be easily accessible. Once the position has been decided the control box should not be moved in day to day use. Standard conduit length supplied is 2m. The EVH 120 is supplied with two control boxes.
|
| |
 |
 |
Click on the the PDF for a printable version of this installation guide |
|